3.7.6.3  Fast Erection Indication - In the SLAVED and DG modes,  the
malfunction  output  signals  shall be present  until completion of the
erection cycle and during activation of fast erection.
3.7.6.4 Negative 28Vdc Malfunction Signals - The negative 28Vdc signals
provided at connector  2J1-22 and 2J3-22 shall have a combined load
capability of 150 milliamps.
3.7.7 Deviation Compensation - A 24-point electrical heading deviation
compensator shall be provided having a nominal adjustment range of 4
and a  repeatable  accuracy of  9 minutes at  each 15 compensation
point.  The deviation compensation-assembly shall be modular and plug-in,
allowing transfer to another electronic control amplifier without major
disassembly of either amplifier and without loss of the stored
compensation information.
3.7.8 Dimensions - The dimensions of the electronic control amplifier
shall be in accordance with figure 3.
3.7.9 Weight - The weight of the amplifier shall not exceed 7.10 pounds.
3.7.10 Elapsed Time Indicator - The electronic control amplifier shall
contain an  elapsed  time  indicator (ETI) conforming to MS17322 and
MIL-M-7793 having a range of at least 9,999 hours.  It shall be visible
without any disassembly of the amplifier per figure 3.
3.7.11 Color - The color of the electronic control amplifier shall be
gray in accordance with FED-STD-595, Color No. 36231.
3.8
Compass System Controllers - The compass system controller shall
The configuration
be designed in accordance with MIL-C-6781, Type 1.
Fasteners shall
shall be in accordance with either figure 4 or 5.
conform  to MIL-F-25173 and plastic plate  lighting  shall conform to
MIL-P-7788, Type IV except as follows:
Paragraph entitled "Connector Location" shall not apply.
a.
The contrast, stray light, and dial visibility requirements
b.
of MIL-L-25467 shall apply.  Stray light shall be measured 1 inch in
front of the panel.
c. the DCK-128/A24G and DCK-234/A24G lighting (white, 4.5V)
shall meet  the  color  requirements  of MIL-L-27160 and the  brightness
requirements of MIL-P-7788.