Click here to make tpub.com your Home Page

Page Title: Switching Rate
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-C-38418E(AS)
Mode switch to SLAVED
Latitude control to 0
Hemisphere switch to N
Compensation switch to OFF
b.
Position the azimuth detector to O.
Depress  and hold the  heading
set  control knob on the
c.
becomes
controller  until  the  indicated  servoed
repeater  heading
synchronized with the azimuth detector.
d.
Reposition the azimuth detector to 340.
The
e.
Measure the dc voltage from connector 2J2-17 to 2J2-18.
dc voltage shall be greater than 8.OVdc.
Measure ac voltages at the tabulated pins of connector 2J2.
f.
Voltages shall be within the following limits:
Volts
(2J2) Pins
8 to 9
6.5 1Vac
8 to 12
108.5 2Vac
Rotate the displacement gyroscope heading transmitter at a
g.
rate of 3 per minute for 1.5 minutes.
(1)
The voltage from connector 2J2-8 to 2J2-9 shall remain
at 6.5 1Vac.
(2)
The voltage from connector 2J2-17 to 2J2-18 shall
remain greater than 8Vdc.
h.
Repeat step g with a rate of -3 per minute for 1.5 minutes.
4.6.4.14.1.1  Switching Rate - The switching rate shall be checked as
follows.
(Note:
During  steps b through d,  the dc voltage may
temporarily become less than 1Vdc while the switching rate is applied.
The time at which this occurs shall not be recorded.)
a.
Set the controls on the controller and the electronic control
amplifier as follows:
67