MIL-C-46577D
4.4.2.2 (Cont)
However, where major defects are considered collectively on a class basis,
the acceptance  number for any individual defect of the class shall be
limited by the assigned Acceptable Quality Level (AQL) for individual
defect associated with the class.  (see 4.4.2.2.1.c) In addition where
MIL-STD is used, sampling plans applicable to a class shall not be used
for major defects.  (see 6.5)
4.4.2.2.1 AQL's. -The following AQL's are assigned to major and minor defects:
Individual:
a.
Major ------------------------------- 0.257%
Minor ------------------------------ 0.40%
b.
Class basis:
Major ------------------------------ 1.50%
Minor ------------------------------ 2.50%
Individual defects associated with the class basis:
c.
Major ------------------------------- 0.40%
4.4.3 Classification of Defects 1/ . - The classification of defects shall
be aS follows:
4.4.3.1 Charged nose assembly (see Dwg. C7258806 and Dwg. D7258803, a
detail of Dwg. D7258802.
Method of Inspection
Category and Defects
Critical:
None defined.
Major:
Length, shoulder to top of charge -------------------- Gage
101.
None defined.
Minor:
6