MIL-C-48469B(AR)
3.3.1 +13V output. With the filter (item 1.5 of table I) connected,
loads connected as specified, and power applied as specified, the filter
output voltage shall be as follows: (see 4.6.2.1)
3.3.1.1 Nominal output voltage. With the load (item 1.1 of table I)
connected and the power source (item 2.2 of table I) set to 24.0 1.2 volts
direct current (vdc) the filter output voltage shall be 12.0 0.1 vdc and
shall have a ripple content not greater than 0.354 volts root mean square
(vrms).
3.3.1.2 Line regulation. With the load (item 1.1 of table I) connected
and the power source (item 2.2 of table 1) varied from 16.75 vdc to 30.00 vdc,
the filter output voltage shall be 12.00 0.36 vdc.
3.3.1.3 Load regulation. With the load (item 1.2 of table I) connected
and the power source (Item 2.2 of table I) set to 24.0 1.2 vdc, the filter
output voltage shall be 12.0 0.2 vdc and shall have a ripple content not
greater  than  0.354  vrms.