MIL-C-50744A(AR)
3.1.3 Ambient Conditions. Standard ambient conditions shall be as
follows:
73 +18F
a. Temperature
b. Relative humidity
50 percent 30 percent
c. Atmospheric pressure
28.5 + 2.0 -3.0 in. Hg.
3.2 First article. When specified (see 6.2), the contractor shall
furnish sample units for first article inspectia and approval (see 4.4 and
6.2).
3.3 Performance. Unless otherwise specified, the assembly shall meet the
performance requirements specified herein under standard  ambient  conditions of
3.1.3.
3.3.1 A-trigger. With the digital type-B signals of table 1 applied to
P1-11 and P1-12 as shown on figure 1, the output signal at P1-10 shall be as
shown on figure 1. (See 4.6.2.1)
3.3.2 Video. With the digital type-B signals of table I applied to P1-7
and Pi-8, as shown on figure 2, the output signal at P1-9 shall be as shown on
figure 2, the output signals at P1-9 shall be as shown on figure 2.
(See 4.6.2.2)
3.3.3 Test range. With the digital type-B signal of table I applied to
P1-32, as shown on figure 3, the output signals at P1-35 and P1-33 shall be as
shown on figure 3. (See 4.6.2.3)