MIL-C-53057(ME)
the examination and tests specified in 4.7 shall be cause for
rejection of the inspection comparison crane(s) and shall be cause
for refusal by the Government to continue acceptance of production
cranes until evidence has been provided by the contractor that
corrective action has been taken to eliminate the deficiencies.
Correction of such deficiencies shall be accomplished by the
contractor at no cost to the Government on cranes yet to be produced
by the contract. Any deficiencies found as a result of the inspection
comparison will be considered prima facie evidence that all cranes
accepted prior to the completion of inspection comparison are
similarly deficient unless evidence to the contrary is furnished by
the contractor and such evidence is acceptable to the contracting
officer. Where cranes previously accepted by the Government are
determined to be deficient, the contractor will negotiate with the
Government to determine the method of correction.
4.8 Inspection of packaging. The preservation, packing, and marking
of the crane shall be inspected as specified in appendix B of
MIL-STD-162.
5. PACKAGING
5.1 Preservation, packing and marking Each crane shall be
.
preserved, packed and marked in accordance with the requirements of
MIL-STD-162 for type I, mobile shipment, and with the exceptions and
qualifications stated herein. The degree of preservation shall be
level A, level B, level C, or commercial; and the degree of packing
shall be level A, level B, or commercial as specified (see 6.2).
Liquid cooling systems shall be preserved by filling with equal parts
of water and antifreeze conforming to MIL A-46153 for all degrees of
-
preservation. Commercial preservation and packing shall comply with
ASTM D 3951. Commercial preservation and packing shall be used only
when it is known that the crane is intended for immediate use by
CONUS consignees.
6. NOTES
6.1 Intended use. The crane is intended for use as a materials
handling crane with a capability of unloading and loading containers
from railroad cars and semitrailers. Operations also include loading
and unloading slung palletized projectiles on ammunition
transporters. The mobility of the crane, without payload, is intended
to cover working areas where high flotation and traction
characteristics are required.
6.2 Ordering data. Procurement documents should specify the
following:
a. Title, number, and date of this specification.
b. Date of issue of DoDISS applicable and exceptions thereto
(see 2.1.1).
c. When first article tests are not required (see 3.2).
d. Time frame required for submission of the first article model
-
and number of cranes required (see 3.2).