4.5.2.3.2 Test Connections.  Unless otherwise specified
herein, all test connections, adjustments and manipulations
specified for a test shall be retained throughout subsequent tests.
4.5.2.3.2.1 Loads.
Connect loads as indicated below:
LOAD
FROM
To
1.5
ohm 2%
1W
DET1 (J1-12)
DET1
(R)
(J1-14)
DET2 (J1-13)
1.5
ohm 2%
1W
DET1
(R)
(J1-15)
See
figure
6
TUBE1 (J1-16)
TUBE1
(R)
(J1-3)
See
figure
6
TUBE2 (J1-17)
TUBE2
(R)
(J1-4)
TUBE3 (J1-18)
See
figure
6
TUBE3
(R)
(J1-5)
See
figure
6
TUBE4 (J1-19)
TUBE4
(R)
(J1-6)
See
figure
6
TUBE5 (J1-20)
TUBE5
(R)
(J1-7)
See
figure
6
TUBE6 (J1-21)
(J1-8)
TUBE6
(R)
TUBE7 (J1-22)
See
figure
6
TUBE7
(R)
(J1-9)
4.5.2.3.2.2 Power source.  Rotate the SAFE/ARM Switch
clockwise to the SAFE position.  Set the output of a O to 15 volt
1 amp DC power supply to 13 0.5 volts.  Connect the negative
terminal to P1-BLK (COMMON) and then the positive terminal to
Pi-RED (+14.4 VDC).
4.5.2.3.3 Lamp test.  Press each of the three indicator
lights on the Control Indicator front panel:  BATT OK, CKT OK and
DATA IN.  Verify that each light is illuminated when depressed and
not illuminated when released.
4.5.2.3.4 Self test.  Rotate the SAFE/ARM switch clockwise to
the TEST position.  Verify that the BATT OK and CKT OK lights are
on within 4 seconds.
4.5.2.3.5 Low voltage detect (LVD) test.  Reduce the voltage
at Pi-RED (+14.4 VDC) to 11.05 0.05 volts.  Verify that the BATT
OK light is on.  Reduce the voltage at Pi-RED (+14.4 VDC) to 10.35
0.05 volts.  Verify that the BATT OK light is off.  Increase the
voltage at Pi-RED (+14.4 VDC) to 13 0.5 volts.
4.5.2.3.6 Load test.  Rotate the SAFE/ARM Switch clockwise to
the load position.  Load a valid field set data (FSD) pattern, as
defined on Drawing 9333026, into the Control Indicator by
applying the pattern to J1-1 (MCD1) with respect to J1-14 (MCD2)
as shown in figure 8.  Verify that the DATA IN light turns on.