MIL-C-70724(AR)
Firing defects.
TABLE IV.
Criteria 1/
Class
None allowed
Critical
BFA blockage
1.
Complete or partial rupture (dwg. 7643674,
2.
locations S, J, K and L)
3.  Detached material (Upon firing)
4.  Burn through
5.  Slamfire
6.  Hazardous Breech Flash or Sparks
7.  Other critical defects 4/
--
Total majors allowed
per 1000 rounds = 2.5
101. Blown or dropped primer
102. Split body or head (dwg. 7643674
locations J, K, L and M)
103. Gas leak at body/head interface
104. Misfire
105. Uncontrolled Fire
106. Breech Flash
107. Other Major defects
Total minors allowed
Minor  (Group A)
per 1000 rounds = 10
201. Split, shoulder (dwg. 7643674, and S)
202. Gas leak through or around primer cup
203. Detached material (upon extraction)
204. Breech Sparks
205. Other minor defects
Total allowed per
Minor  (Group B)
1000 rounds = 10
206. Stoppages (attributable to ammunition)
Notes:
This table shall be applied separately to the results of
each weapon type at each temperature condition.
A slamfire occurs when a round is unintentionally fired
by manually closing the weapon bolt, without depressing the
trigger of the weapon.
30