MIL-C-81360(AS)
In the step type of release, the pulse width shall be determinedly the pilot. The leading
edge of the release pulse shall occur when the pilot manually starts a step drop. The trail-
ing edge of the pulse shall occur when the pilot manually ends the drop.
Quantity Select - The number of release output pulses generated by the
3.4.5
system shall be pilot controlled.  The pilot, when desiring a drop of any amount of stores,
shall be able to select the exact amount of from 2 to 40 output pulses to be generated in
amounts limited to the following steps:
(1) 1, 2, 3, 4, 5, 6 (steps of one)
(2) 8, 12, 16, 20 (steps of four)
(3) 30, 40 (steps of ten)
Detailed Requirements -
3.5
3.5.1
Control, Aircraft Weapons Release Set C-6682(*)/AWE-1 - The control
shall meet the following requirements:
Function - The control is the unit of the system which selects the operat-
3.5.1.1
ing modes of the system. The control shall determine the following:
(1) The quantity of stores to be released, as tabulated in 3.4.5.
(2) The drop interval which shall range from 20 to 2000 milliseconds.
(3) The mode and type of release as tabulated in 3.4.2.
Form Factor - The control shall conform to the dimensions and require-
3.5.1.2
ments shown in Figure 2.  It shall be mounted in the cockpit.
3.5.1.3
Weight - The weight of the control shall not exceed 1.25 pounds.
3.5.1.4
Contents - The control shall contain the electronics to provide an external
intra-system 28 volt pulse train whose frequency shall be controlled by the drop interval
select knob of 3.5, 1.5. The width of this pulse shall be as specified in 3.4.4.1.
3.5.1.5
Controls - All controls and select switches are located and identified as
in Figure 2. The controls and switches perform the following functions.
Reference
Designation
Function
QTY - SEL
Quantity select and system turn on
DROP INTVL
Drop interval in milliseconds
MULT SW
Drop interval multiplier switch
MODE SELECT
Determines mode of operation