MIL-D-63303B(AR)
Long Self Destruct
(1) Between pin A and ground, 28 0.3 volts.
(2) Between pin B and ground, 0 volts.
(3) Between pin C and ground, 20 ohm, maximum (max.)
During application of 28  0.3 volts to pin D and pin E of
connector P10, the TAPS malfunction indicator lights, right and left
respectively, shall not be illuminated.
3.4.2.5.7 Controls.  When installed in accordance with
applicable drawings, all electrical, mechanical and hydraulic
controls shall operate without malfunction throughout all ranges of
operation under all dispenser operating conditions.
3.4.2.5.7.1 Control panel malfunction warning and automatic
shut down system.  Malfunction lamp (red) on the Control Panel shall
illuminate when the following malfunctions occur:
a.  High Coolant Temperature-Dispenser shut down temperature
0
shall occur between 206 and 219 F (97 and 104C)
inclusive.  Malfunction lamp shall illuminate before shut down
0
at not lower than 197F (92 C).
b. Low Enginr Oil Pressure, less than 6.0
2.0 psi (0.42
0.14 kg/cm2).
Low fluid level in the reservoir.
c.
d.  TAPS malfunction - In addition, the individual magazines
shall shut down depending on which coil of the TAPS failed.
n
e.  "Runaway Maqazine Shutdown.  In addition to the affected
magazine(s) stopping 1.5 0.3 sec. after the "FIRE" switch is
returned to the "OFF" position, the TAB failure light on the
BITE/ALARM panel shall illuminate, indicating which magazine
(right or left) is not sending a tab sensor signal.
Magazine(s) shall not "creep" when the "FIRE" switches are in
the "OFF" position.
The dispense mode will shut down when the launcher wheel
NOTE:
speed falls below 800 RPM.
3.4.2.5.8 Liqhts and accessories.  The internal and external
lights and electrical accessories, including cables and receptacles,
shall function throughout all dispenser operating conditions. All
electrical contacts and connections shall maintain positive contact
under all dispenser conditions.