MIL-E-1/83G
MIL-STD-1311
Requirement or test
Conditions
Symbol
Units
Limits
Test method
Min
Max
Conformance inspection,
part 1 - Continued
ib
16
---
a
---
Operation
Ebb = 500 V dc
(approx);
egy = 100 v;
epy = 1,000 v;
Ecc1 = -50 V dc
Ecc2 = 0;
prr = 500;
Zo = 25 5 percent;
Rl = 20 5 percent
8/
Conformance inspection,
part 2
1211
Insulation of electrodes
Ef = 6.3 V;
R
760
---
Meg
Eg2-p = 380 V dc
9/
1121
Base strain
---
---
---
---
2126
Envelope strain
3/
---
---
---
---
1031
High-frequency vibration
No voltages applied;
---
---
---
---
fixed amplitude
= 0.0625 0.0025
1041
Shock
720 G
---
---
---
---
---
Shock-test end points:
A dc
1336
Heater-cathode leakage
Ehk = +25 V dc
Ihk
---
40
A dc
Ehk = -100 V dc
Ihk
---
40
3201
Critical anode voltage
Ebb
---
50
V dc
for conduction (1)
1231
Pulse emission
Etd
---
76
v
3201
Critical anode voltage
Ecc1
-2.9
-4.5
V dc
for conduction (1)
Ecc1
---
-6.4
V dc
3201
Critical grid voltage
Ef = 7.0 V;
for conduction (3)
Epp = 460 V ac;
Rg1 = 10 Meg;
Rp = 3,000 ohms
5/ 6/ 10/
Ebb
---
50
V dc
3201
Critical grid voltage
Ef = 5.7 V;
for conduction (3)
Ecc1 = 0;
Rg1 = 0.1 Meg;
Rp = 1,000 ohms
5/ 11/
1261
Electrode voltage
Epp = 150 V ac;
Egg2
1.9
3.3
V ac
(grid no. 2)
Egg1 = 16 V ac;
Rp = 1,000 ohms;
Rg1 = 2,500 ohms
12/ 13/
See footnotes at end of table.