MIL-E-23765B(SH)
5.1.1.8 Packaging for flux.  Flux shall be suitably packaged to ensure
against damage during shipment and storage under normal conditions.  Flux in
Its original unopened containers, shall withstand storage under normal condi-
tions for at least 6 months without damage to its welding characteristics or
the properties of the weld.  Heating of the flux may be necessary to assure
dryness.
5.1.2 Level C packaging
5.1.2.1 All classes of electrode and rod.  Packaging shall be sufficient
to afford protection against physical damage during shipment from the contractor
to the using activity (see 6.5.4) and until early use.
Packing shall be level A, B, or C as specified (see 6.2.1).
5.2 Packing
5.2.1 Level A.  Electrodes and rods shall be packed in accordance with
level A of MIL-W-10430.
5.2.2 Level B.  Electrodes and rods shall be packed in accordance with
level B of MIL-W-10430,
5.2.3 Level C.  Packing shall be accomplished In a manner which shall
ensure acceptance by common carrier and afford protection against physical or
mechanical damage during direct shipment from the contractor to the using
activity for early use.  The shipping containers or method of packing shall
conform to the Uniform Freight or National Motor Freight Classification Rules
or other carrier rules as applicable to the mode of transportation.
5.3 Marking.  In addition to any special marking required by the contract
or order (see 6.2.1) or herein, interior containers (packages) and exterior
shipping containers shall be marked in accordance with MIL-STD-129.
5.3.1 Special marking.
5.3.1.1 Interior packages.  Shipment marking information for electrodes
and granular flux shall be provided on interior packages.  The information
shall include lot identification, type, size when applicable, specification
number, manufacturer  s or distributors name, manufacturer's or distributor's
brand or type designation.  In addition, all packages or the smallest integral
unit within a shipping container, shall carry the following warning label, or
equivalent , prominently displayed in legible type on the package: