MIL-E-50739(MU)
8 August 1973
4. 5.2 Contractor furnished inspection equipment.
4.5.2.1 Government design. Unless otherwise specified in the
contract, all inspection equipment specified by drawing number in specifi-
cations or SQAPS forming a part of the contract shall be supplied by the
contractor in accordance with applicable technical data listed in the TDP.
4.5.2.2 Contractor design. The contractor shall design and supply
inspection equipment compatible with the test methods and procedures
specified in 4.6 of this specification and with the component inspection
procedures specified in examination and test facilities provisions of MIL-F-
13926. Since tolerance of inspection equipment is normally considered to
be within 10 percent of the product tolerance for which intended, this inher-
ent error in the inspection equipment design must be considered as part of
the prescribed product tolerance limit. Thus, concept, construction,
materials, dimensions and tolerances used in the design of inspection equip-
ment shall be so selected and controlled as to insure that the inspection
equipment will reliably indicate acceptability of a product which does not
exceed 90 percent Of the prescribed tolerance limit and permit positive
rejection when ono-conforming. Construction shall be such as to facilitate
routine calibration of inspection equipment,
4.6 Test methods and procedures
4.6.1 Test conditions. Unless otherwise specified, the test con-
ditions shall be in accordance with the test facilities provisions of MIL-F-
13926.
4.6.1.1 Initial conditions. Connect the loads, power source and
signal source to the assembly as specified in table I. Unless otherwise
specified, set the voltage of  the power source specified in table I (item 2.1)
to +24.0 2.0 Vdc.