4.3.1  Examinations  The first article shall be examined as specified in
4.5.1. Presence of one or more defects shall be cause for rejection.
4.3.2 Tests.  The first article shall be tested as specified in 4.5.2.
Failure of any test shall be cause for rejection.
4.4
Quality conformance inspection.
4.4.1 Sampling.  Sampling for inspection shall be in accordance with
MIL-STD-105.
Sample size shall be determined by using MIL-STD-105, table I
and table IIa.  A lot shall be accepted when O defects are found and rejected
when one or more defects are found.
4.4.2 Examination.  Sample selected in accordance with 4.4.1 shall be
examined for the defects specified in 4.5.1.  Presence of one or more defects
shall be cause for rejection.
4.4.3 Tests.  Samples selected in accordance with 4.4.1 shall be tested as
specified in 4.5.2.  Failure of any test shall be cause for rejection.
4.5 Inspection procedure.
4.5.1 Examination.  The primer equipment shall be examined as specified
herein for the following defects:
Materials not as specified (see 3.3).
101.
102.
Materials not resistant to corrosion and deterioration, or treated
to be resistant to corrosion or deterioration of the applicable
operating and storage environments (see 3.3.1).
Dissimilar metals as defined in MIL-STD-889 are not effectively
103.
insulated from each other (see 3.3.1.1).
Contractor does not have documentation available for identification
104.
of materials, material finishes, or treatment (see 3.3.1.2).
Used, rebuilt, or remanufactured components, pieces, and parts
105.
incorporated in the primer equipment (see 3.3.2).
Type and size of primer equipment not as specified (see 3.5
106.
and 3.6).
107.
Safety accessories not as specified (see 3.7 and 3.8).
Treatment and painting not as specified (see 3.9).
108.
Identification markings not as specified (see 3.10).
109.
110.
Workmanship not as specified (see 3.11).
4.5.2 Tests.
Tests shall be conducted in the following order.
4.5.2.1 Diethyl ether stability.  Gaskets, O-rings, moldings, and all non-
metallic material utilized in any sample primer equipment shall be tested for
stability in ether as follows: