MIL-F-15733/64A
Voltage drop: Not applicable.
Insertion-loss: In accordance with MIL-PRF-15733 and table I.
Overload: In accordance with MIL-PRF-15733. Measurements at +25C after test:
Insulation resistance only shall be measured and shall meet initial requirements.
Terminal strength: In accordance with MIL-PRF-15733 and method 211, MIL-STD-202; test condition A.
Applied force: 5 pounds.
TABLE I. Insertion-loss versus frequency.
Minimum no-load insertion-loss (dB) at +25C.
Dash
number
10
20
100
400
1
10
MHz
MHz
MHz
MHz
GHz
GHz
0001
25
40
70
65
65
65
Salt atmosphere (corrosion): In accordance with MIL-PRF-15733 and method 101, MIL-STD-202; test condition B,
Thermal shock and immersion: In accordance with MIL-PRF-15733 except that the insulation resistance after the
final cycle shall be 1,000 Megohms minimum.
Shock (specified pulse): In accordance with MIL-PRF-15733 and method 213, MIL-STD-202; test condition I.
Vibration, high frequency: In accordance with MIL-PRF-15733 and method 204, MIL-STD-202; test condition D (20 G),.
Moisture resistance: Not applicable.
Life: In accordance with MIL-PRF-15733 and method 108, MIL-STD-202; test condition D. The following exception
shall apply:
Measurements after test:
Insulation resistance shall be not less than 1,000 megohms.
Part or Identifying Number (PIN): M15733/64-0001.
Marking: Filters shall not be marked. Full marking, in accordance with MIL-PRF-15733, shall be marked on the unit
package.
Qualification inspection: Qualification inspection is not applicable to this document.
Conformance inspection: Group A inspection only shall be performed. This does not relieve the product from
conforming to the group C requirements.
Supersession data: Filters in this specification supersede filters in MIL-F-15733/50 as follows:
MIL-F-15733/50
MIL-F-15733/64
PIN
PIN
M15733/50-0003
M15733/64-0001
3