Click here to make tpub.com your Home Page

Page Title: Duration of pulse
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-F-48235 (MU)
be rejected if any assembly exhibits any defect listed in Table I.
The test shall be performed as specified in 4.4.3 using test equip-
ment in accordance-with 4.3.4.  (Non-Destructive)
4.3.3.1.3 Duration of pulse (see 3.5.lc) - Major defect -
Code No. 18014. - Twenty (20) firing devices shall be selected
from each lot for test.  The lot shall be rejected if any as-
sembly fails to comply with the requirements.  The test shall
be performed as specified in 4.4.3 using test equipment in ac-
cordance with 4.3.4,  (Non-Destructive)
4.3.3,2 Embrittlement of springs (see 3.3) - Major defect.
Thirty (30) springs of each type shall be selected from each
lot for this test.  If one or more springs of one type fail to
comply with the specified requirements, the lot shall be rejected.
The test shall be performed as specified in 4.4.1 using equipment
in accordance with 4,3,4.  (Destructive test) Springs shall not
be returned to the lot.
Code No.
Component
09008
Cap spring (8800948)
a.
08008
Actuator spring (8800945)
b.
11008
Armature spring (8837123)
c.
23001
Bail spring (8800935)
d.
24001
Bail latch spring (8800944)
e.
4.3.3.3 Air leaks (see 3.4) - Major defect - Code No. 18015.
This test shall be performed 100 percent.  Any firing device which
fails to comply with the specified requirements shall be classed
defective and removed from the lot.  The test shall be performed
as specified in 4.4.2 using equipment and procedures in accordance
with dwg. 9200408.  (Non-Destructive)
4.3.3.4 Load test of male connector (see dwg. 9272095) -
Major defect - Code No. 25005. - Fifty (50) connectors shall be
selected from each lot for test.  The lot shall be rejected if
any connector fails to comply with the requirements.  The test
shall be performed as specified in 4.4.4 using test equipment in
accordance with 4.3.4. (Non-Destructive)
21

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business