Page Title: Bond Strength
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-F-48267 (PA)
4.4.1 Bond Strength. - The IC shall be tested for the
requirements of Method 2011.1, Test Condition D of MIL-STD-883
using Government approved test equipment.  Any IC failing to
comply with all of the requirements of 3.4 shall be classed
defective.  Testing is destructive and devices tested shall
not be returned to the lot.
4.4.2 Lead Fatigue. - The IC shall be tested for the
requirements of Method 2004, Test Condition B2 of MIL-STD-883
using Government approved test equipment.  Any IC failing to
comply with all of the requirements of 3.5 shall be classed
defective.  Testing is destructive and devices classed defec-
tive shall not be returned to the lot,
4.4.3 Conditioning Screen Tests. - The IC shall be sub-
jected to the required tests using only Government approved
test equipment.  Any IC failing to comply with all of the re-
quirements of 3.6 shall be classed defective.  Testing is non-
destructive and only IC's that pass all of the specified tests
shall be returned to the lot.
4.4.4 Pre-Burn-In Static Electrical Parameter Tests. -
The IC shall be tested for the specified requirements of 3.7
using a Teredyne IC Test Set No. J283 with H260 test check with
36 channel capacity, and the load card of drawing 9278639.  The
test conditions and limits shall be placed on a Tri-Data 10 foot
tape No. 1010 or equivalent tape compatible with the test equipment.
Any IC failing to comply with all of the specified requirements
of 3.7 shall be classed defective.  Testing is non-destructive
and only accepted IC's shall be returned to the lot.
4.4.5 Burn-In Tests. - The IC shall be tested for the
specified requirements of 3.8 using approved tests racks and
sockets in accordance with drawing 9278840.  Testing is non-de-
structive and IC's shall be sent to final electrical testing of
4.3.3.6.
4.4.6 Group A Final Static Ambient Electrical Parameters. -
the IC shall be tested for the specified requirements of 3.9
using a Teredyne IC Test Set No. J283 with H360 test check with
36 channel 'capacity and the load card of drawing 9278639. The
test conditions and limits shall be placed on a Tri-Data 10 foot
tape No. 1010 or equivalent tape compatible with the test equipment.