MIL-F-48877A (AR)
TABLE III.
Module time delay test.
All modules shall be serialized.
1.
2.
A setter that represents the helicopter setter system
shall be used for acceptance of all modules.
The firing capacitor shall be checked to insure that at
least minimum detonator firing output pulse is present
when the detonator firing circuit is tripped at the
conclusion of the time delay.
3.
The module timing circuit shall be tripped immediately
following the charging of each module.
4.
Modules shall be temperature conditioned for a minimum
of two (2) hours after stabilization at the temperatures
specified in paragraph 2 above.