MIL-F-63281A (AR)
5.  Modules shall be temperature conditioned for a minimum of two (2)
hours after stabilization at temperature specified in Section 4 above.
6.  All modules shall be checked for module turn on time.  Data
obtained from these checks shall be recorded and be made traceable to
individual modules.
7.  A seven (7) second time delay shall follow the charging of each
module and before the module timing circuit is tripped.
8.  Additional nominal time settings (at ambient temperature) shall
be used for informational purposes only, the nominal time settings
are as follows:  50MSec, 100MSec, 300MSec, 400MSec, 500MSec. Both
setters shall be used. Modules that were tested at ambient
temperature in the preceding segment (Section 4 above) may be used
for this test segment.