MIL-L-12997F(AR)
Plate, Special Flat
8409284
Ring Gage, Go
8415842
Ring Gage, Not Go
8415843
Flat Plug Gage
8415858
Double End Snap Gage
8415859
(Copies
of specifications, standards, d r a w i n g s , and publications
required
by suppliers in connection with specific procurement
functions
should be obtained from the procuring activity or as
directed
by the contracting officer.)
2 . 1 . 3 O t h e r p u b l i c a t i o n s .  The following documents form a
part of this specification to the extent specified herein. Unless
o t h e r w i s e indicated, t h e issue in effect on date of invitation for
b i d s or request for proposal shall apply.
AMERICAN SOCIETY FOR TESTING AND MATERIALS
ASTM E18 -
Test for Rockwell Hardness and
R o c k w e l l Superficial Hardness of
Metallic Materials
ASTM B117 -
M e t h o d of Test for Salt Spray (Fog)
Testing
( A p p l i c a t i o n for copies should be addressed to the American
S o c i e t y for Testing and Materials, 1916 Race Street, Philadelphia,
PA 19103).
T e c h n i c a l society and technical association specifications and
s t a n d a r d s are generally available for reference from libraries.
T h e y are also distributed among technical groups and using federal
agencies.
2.2 Order of precedence.  I n the event of a conflict between
t h e text of this specification and the reference cited herein, the
t e x t of this specification shall take precedence.
REQUIREMENTS
3.
3 . 1 M a t e r i a l s .  M a t e r i a l s shall be in accordance with the
a p p l i c a b l e drawings and specifications.
T h e links shall comply with all requirements
3.2 Components.
s p e c i f i e d on drawing 7147028 and associated drawings and with all
r e q u i r e m e n t s specified in applicable specifications and standards.
3 . 3 P u l l .  L i n k s shall be capable of withstanding 600 + 25
p o u n d s tensile load without fracture. When tensile load is
applied, the distance X-X as shown on Drawing 7147028 shall not
e x c e e d 1.945 inches at load and the bridge shall be tight on the
b o d y after test. Testing shall be as specified in 4.5.1.