Click here to make tpub.com your Home Page

Page Title: Inspections to be performed
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




MIL-L-48063A(MI)
Ten (10) launchers as follows:
a.
(1) All-Initial Examination (4.4.14.1).
(2) Two (2) in accordance with High Temperature , (4.4.14.2), Low
Temperature, (4.4.14.3), and Static Load, (4.4.14.9).
(3) Two (2) in accordance with Vibration, (4.4.14.6), and Static
Firing, (4.4.14.10).
(4) Two (2) in accordance with Flight Firing, (4.4.14.11).
(5) Two (2) in accordance with Shock, (4.4.14.5), and Static Firing,
(4.4.14.10).
(6) Two (2) in accordance with Salt Fog, (4.4.14.8), and Rough
Handling, (4.4.14.7).
b.
Twelve (12) intervalometers as follows:
(1) ALL in accordance with Electrical Tests, (4.4.6).
(2) ALL in accordance with Simulated Firing Test, (4.4.7).
(3) ALL in accordance with Bypass Test, (4.4.8).
(4) Two (2) in accordance with Humidity, (4.4.9.1).
(5) Two (2) in accordance with Sand and Dust (4.4.9.2).
(6) Two (2) in accordanca with Shock, (4.4.9.3).
(7) Two (2) in accordance with Salt Fog, (4.4.9.4).
(8) Two (2) in accordance with Acceleration, (4.4.9.5).
(9) Two (2) in accordance with Life, (4.4.9.6).
c. Eight (8) additional intervalometers, when intervalometers are
being procured separately, as follows:
(1) ALL in accordance with Electrical Tests, (4.4.6).
(2) ALL in accordance with Simulated Firing Test, (4.4.7).
(3) ALL in accordance with Bypass Test, (4.4.8).
(4) Four (4) in accordance with High Temperature, (4.4.9 .-) and Low
Temperature, (4.4.9.8).

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business