MIL-L-48385 (PA)
4.4.3 Testing
4.4.3.1 Pull test of crimped connections. - (See dwg.
9269004), Major A defect.  Fifty (50) connectors shall be
selected from each lot for test.  The lot shall be rejected
if any connector fails to comply with the requirements.  The
test shall be performed as specified in 4.5.1 using test equip-
(Non-destructive)
ment in accordance with 4.4.4.
4.4.3.2 Resistance of extension line. - (see dwg. 9269004)
Major A defect.  This test shall be performed 100 percent as
specified in 4.5.2 using equipment in accordance with 4.4.4.
Any assembly which fails to comply with the specified require-
ment shall be classed defective and removed from the lot.
(Non-destructive test).
4.4.4 Inspection Equipment. - The inspection equipment re-
quired to perform the inspections and tests prescribed In this
specification is identified in the 'Paragraph Reference/Inspection
Method' column in the tables starting with paragraph 4.4.2.1, and
the test method paragraphs (see 4.5).  The contractor shall submit
for approval, inspection equipment designs in accordance with the
terms of the contract.  See Section 6 of MIL-A-48078 (PA).
4.4.5 Dimensional control of molded parts. - (The require-
ments of this paragraph apply to those dimensions which are
considered "as molded", and which do not undergo subsequent
operations).  In place of normal sampling and inspections as-
sociated with the Classification of Defects, and with the ap-
rpoval of the Contracting Officer, and after a curing time for
the parts has been approved (see Note 1) a sample of five (5)
parts (as molded) from each cavity shall be inspected dimen-
sionally to qualify a new or reworked cavity for use in
production.  The molded parts shall carry the individual cavity
identification, when more than one cavity is used in production.
AS a control of each cavity during production, the above quantity
of parts from each cavity shall be inspected for at least the
defects listed in paragraphs 4.4.5.1 through 4.4.5.3 after
continuous production of each 5,000 parts or at the end of
each week, whichever occurs first.  Of the five (5) samples,
one (1) sample shall be the last part produced.  If any defective
parts are found during qualification of the cavity, the cavity
producing the defective part will not be used in production. If
any defective parts are found when inspection is performed for
11