MIL-L-81795(AS)
Individual Tests - Individual tests shall be accomplished under the
4.3.1
responsibility of the contractor, on each launcher submitted for acceptance
under the contract. The contractor shall maintain test reports showing the
quantitative results for individual tests.  Such reports shall be signed
by an authorized representative of the contractor and.this data shall be made
available to the procuring activity upon request.  Individual tests shall con-
sist of the following:
(1) Examination of Product (4.5.1)
(2) Functional Tests (4.5.2)
.
Sampling Tests - Sampling Tests shall be conducted at a Government
4.3.2
designated laboratory facility under the responsibility of the procuring
activity.  Sampling tests shall be conducted on samples selected from lots
of equipment which have passed the individual tests,  Samples to be tested
shall be selected at random by the Government Inspector in accordance with
the following lot schedule and forwarded to the designated laboratory facility
for testing.  Sampling tests shall consist of all tests of 4.5.
4.3.2.1
Lot - For inspection and test purposes, the quantities listed below
shall comprise the lot sizes and the number of test samples to be inspected
from each lot.
Quantity Offered for
to be tested
Lot Acceptance
1
1-125
I
2
125-300
4
300-500
- If any sample fails to pass the tests specified
Reflection and Retest
4.3.3
herein, another random sampling
of the same size will be submitted. Failure of
the entire lot to be rejected.  Rejected lots
the second sampling shall cause
may be reworked and resubmitted
for retest upon approval by the Naval Air Systems
Command.
4.4
Test Conditions - Except where otherwise specified, all tests required
by this specification shall be made at normal room temperatures and barometric
pressure, with a relative humidity of 80 percent or less.
Test Power - The power source for firing tests shall be 20-30 volts DC
4.4.1
supplied through a 5-ohm resistor.
Test Methods
4*5
Examination of Product - Each launcher shall be examined for conformance
4.5.1
to the drawings and this specification with respect to workmanship, dimensions,
marking and examination of the following:
-7-