MIL-L-82452A(OS)
3.3 Design and construction.  The design and construction of the Logic
Assembly, Type I and Type II, shall be in accordance with PL 5547531 or PL
6098364 (see 6.2).
3.4 Performance characteristics.
The numerical values tabulated in column I of the following tables are
NOTE:
applicable to the tests conducted in accordance with the acceptance
test and examinations of 4.7.  The values in column II are applicable
to the tests of paragraph 4.5.2.3.2. and table VIII, test sequence 10.
Minimum and maximum values apply to absolute values only (i.e., -40.6
volts direct current (Vdc) is greater than -40.1 Vdc).
3.4.1 Inputs.  The Logic Assembly shall require or accept the inputs
given in table I and shall meet all functional requirements with the dc inputs
given:
TABLE I. DC inputs.
3.4.1.1 Signal inputs.  The Logic Assembly shall operate with the
signal inputs given in table II.  Those signals that are digital in their
operation are shown in both states.
TABLE II.