MIL-L-85347A(AS)
4.5  Quality conformance inspection.  The sampling and inspection levels
The quality conformance inspection shall
shall conform to MIL-STD-105.
consist of the following:
a. Visual examinations of the life preservers
b. Operation (carbon dioxide)
Pressure
Leakage
e. Bouyancy
f. Dimensional check of the life preservers
g. Preparation for delivery
4.5.1
Sampling.
4.5.1.1 Inspection lot.
4.5.1 .1.1 Adhesive.  An inspection lot size shall be expressed in units of
one batch of the adhesive.  An Inspection lot shall consist of all the batches
of the adhesive used by the life preserver manufacturer during one day's
The sample unit shall be one
production of the life preservers (see 3.4.4).
batch of the adhesive used during one day's production of the life preservers.
4.5.? .1.2 Life preservers.  An inspection lot size shall be expressed in
units of one life preserver made essentially under the same conditions and
from the same materials and components.  The sample units shall be one life
preserver.
4.5.1 .1.3 Preparation for delivery.  An inspection lot size shall be
expressed in units of one fully prepared shipping container, including life
preservers, fully prepared for delivery from essentially the same materials
and components.  The sample units shall be one shipping container, including
life preservers fully prepared for delivery with the exception that it need
not be sealed.
4.5.1.2 Sampling for tests and examination of the components and the life
preservers and preparation for delivery.  The sample size, acceptance
criteria, tests, and examinations required for the components, the life
preservers of the preparation for delivery shall be as specified in table III
and 4.5.1.3.
4.5.1.3  Quality conformance verification inspection.  Upon completion of
the tests and examinations specified in 4.5.1.2, a random sample shall be
Inspection Level S-3,
selected from each lot in accordance with MIL-STD-105.
(see 6.2.lk).  The sample size shall be based only on the applicable sample
size code letter corresponding to the Inspection Level S-3. Each life
preserver selected as a sample unit shall be identified by its assigned serial
number (see 3.8.2), and shall be forwarded to the Government Laboratory
specified In the procurement document (see 6.2.lg), for the following tests
and examinations (listed sequence mandatory):
TESTS AND EXAMINATIONS
(4.7.2)
OPERATION
I
(4.7.3)
PRESSURE
(4.7.4)
LEAKAGE
(4.7.1.1)
VISUAL EXAMINATION
(4.7.1.1)
DIMENSIONAL CHECK
10
I
\

Privacy Statement - Press Release - Copyright Information. - Contact Us