TABLE II. Electrical test requirements.
MIL-PRF-38535
Subgroups (see table III)
test requirements
Class S
Class B
devices
devices
Interim electrical parameters
1
1
Final electrical test parameters 1/
1,2,3,4
1,2,3,4
Group A test requirements
1,2,3,4,7
1,2,3,4,7
Group B electrical test parameters
1,2,3, and
N/A
when using the method 5005 QCI
table IV delta
option
limits
Group C electrical parameters
1,2,3, and
1 and
table IV delta
table IV delta
limits
limits
Group D end point electrical
1,2,3
1
parameters
1/ PDA applies to subgroup 1.
4.4.3 Group C inspection. Group C inspection shall be in accordance with table IV of MIL-PRF-38535 and as follows:
a.
End point electrical parameters shall be as specified in table II herein. Delta limits shall apply to group C
inspection for classes B and S devices.
b.
The steady-state life test duration, test condition, and test temperature, or approved alternatives shall be as
specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall
be maintained under document control by the device manufacturer's Technology Review Board (TRB) in
accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request.
The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with
the intent specified in test method 1005 of MIL-STD-883.
4.4.4 Group D inspection. Group D inspection shall be in accordance with table V of MIL-PRF-38535 and as follows:
a.
End point electrical parameters shall be as specified in table II herein.
b.
Constant acceleration (method 2001 of MIL-STD-883); test condition B shall be used for case Y.
4.5 Methods of inspection. Methods of inspection shall be as specified and as follows.
4.5.1 Voltage and current. All voltage values given are referenced to the designated return sense line. Currents given
are conventional current and positive when flowing into the referenced terminal.
19