MIL-M-38510/2G
8/ Input condition Clear for device types 05 and 07.
9/ See table III for complete terminal conditions.
10/ Minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of
the input frequency.
11/ For device types 02 and 03,limits are 0 to 120 A.
TABLE II. Electrical test requirements.
Subgroups (see table III)
MIL-PRF-38535
Class S
Class B
test requirements
devices
devices
Interim electrical parameters
1
1
Final electrical test parameters
1*, 2, 3, 7,
1*, 2, 3,
8, 9
7, 9
Group A test requirements
1, 2, 3, 7, 8,
1, 2, 3, 7
9, 10, 11
9
Group B test when using the method 5005
1, 2, 3,
N/A
QCI option
Group C end-point electrical
1, 2, 3,
1, 2, 3
parameters
Additional electrical subgroups for
N/A
10, 11
Group C periodic inspections
Group D end-point electrical parameters
1, 2, 3
1, 2, 3
*PDA applies to subgroup 1.
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-
38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM
plan shall not effect the form, fit, or function as described herein.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38535 and shall be conducted on all devices
prior to qualification and quality conformance inspection. The following additional criteria shall apply:
a. The burn-in test duration, test condition, and test temperature, or approved alternatives shall be as
specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test
circuit shall be maintained under document control by the device manufacturer's Technology Review
Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or
preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power
dissipation, as applicable, in accordance with the intent specified in test method 1015 of MIL-STD-
883.
b. Interim and final electrical test parameters shall be as specified in table II, except interim electrical
parameters test prior to burn-in is optional at the discretion of the manufacturer.
c. Additional screening for space level product shall be as specified in MIL-PRF-38535, appendix B.
4.3 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-38535.
4.4 Technology Conformance inspection (TCI). Technology conformance inspection shall be in accordance
with MIL-PRF-38535 and herein for groups A, B, C, and D inspections (see 4.4.1 through 4.4.4).
5