Page Title: Figure 8. Clear and preset switching test circuit and waveforms for device type 04.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-M-38510/2G
NOTES:
1. Clear or preset inputs dominate regardless of the state of clock or J-K inputs.
2. Clear or preset input pulse characteristics: Vgen = 3 V, t0 = t1 = 10 ns, tp(clear) = tp(preset) = 30 ns, PRR = 1
MHz, and ZOUT 50.
3. CL = 50 pF, minimum (including jig and probe capacitance).
4. RL = 3905%.
5. All diodes are 1N3064, or equivalent.
6. When testing clear to output switching, preset input shall have a negative pulse. When testing
preset to output switching, clear input shall have a negative pulse (see table III).
FIGURE 8. Clear and preset switching test circuit and waveforms for device type 04.