Page Title: Table 2. Electrical test requirements.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-M-38510/316E
TABLE II. Electrical test requirements.
Subgroups (see table III)
MIL-PRF-38535
Class S
Class B
test requirements
devices
devices
Interim electrical parameters
1
1
Final electrical test parameters
1*, 2, 3, 7, 9,
1*, 2, 3, 7, 9
10, 11
Group A test requirements
1, 2, 3, 7, 8,
1, 2, 3, 7, 8,
9, 10, 11
9, 10, 11
Group B electrical test parameters
1, 2, 3, 9,
N/A
when using method 5005 QCI option
10, 11
Group C end-point electrical parameters
1, 2, 3, 9,
1, 2, 3
10, 11
Group D end-point electrical parameters
1, 2, 3
1, 2, 3
*PDA applies to subgroup 1.
4.4.2 Group B inspection. Group B inspection shall be in accordance with table II MIL-PRF-38535.
4.4.3 Group C inspection. Group C inspection shall be in accordance with table IV of MIL-PRF-38535 and as follows:
a. End-point electrical parameters shall be as specified in table II herein.
b. The steady-state life test duration, test condition, and test temperature, or approved alternatives shall be as
specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit
shall be maintained under document control by the device manufacturer's Technology Review Board (TRB) in
accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon
request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in
accordance with the intent specified in test method 1005 of MIL-STD-883.
4.4.4 Group D inspection. Group D inspection shall be in accordance with table V of MIL-PRF-38535. End-point
electrical parameters shall be as specified in table II herein.
4.5 Methods of inspection. Methods of inspection shall be specified and as follows:
4.5.1 Voltage and current. All voltages given are referenced to the microcircuit ground terminal. Currents given are
conventional and positive when flowing into the referenced terminal.