| TABLE III. Group A inspection for device type 03.
Terminal conditions (pins not designated may be high ≥ 2.0 V; low ≤ 0.7 V; or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
E, F
Subgroup
Symbol
883
Cases
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2, X
terminal
Test no.
A
B
C
Q0
Q1
Q2
Q3
GND
Q4
Q5
Q6
Q7
DATA
Min
Max
VCC
ENBL
CLR
IN
Same tests, terminal conditions, and limits as for subgroup 1 except TC = +125C and VI C tests are omitted.
2
Same tests, terminal conditions, and limits as for subgroup 1 except TC = -55C and VI C tests are omitted.
3
7 2/
Truth
3014
50
B
B
B
L
L
L
L
GND
L
L
L
L
A
A
B
5.0 V
3/
Tc = 25C table
"
51
B
"
"
H
"
"
"
"
"
"
"
"
"
B
"
"
"
tests
"
52
A
"
"
L
"
"
"
"
"
"
"
"
"
A
"
"
"
"
53
A
"
"
"
H
"
"
"
"
"
"
"
"
B
"
"
"
"
54
B
A
"
"
L
"
"
"
"
"
"
"
"
A
"
"
"
"
55
B
"
"
"
"
H
"
"
"
"
"
"
"
B
"
"
"
"
56
A
"
"
"
"
L
"
"
"
"
"
"
"
A
"
"
"
"
57
A
"
"
"
"
"
H
"
"
"
"
"
"
B
"
"
"
"
58
B
B
A
"
"
"
L
"
"
"
"
"
"
A
"
"
"
"
59
B
"
"
"
"
"
"
"
H
"
"
"
"
B
"
"
"
"
60
A
"
"
"
"
"
"
"
L
"
"
"
"
A
"
"
"
"
61
A
"
"
"
"
"
"
"
"
H
"
"
"
B
"
"
"
"
62
B
A
"
"
"
"
"
"
"
L
"
"
"
A
"
"
"
"
63
B
"
"
"
"
"
"
"
"
"
H
"
"
B
"
"
"
"
64
A
"
"
"
"
"
"
"
"
"
L
"
"
A
"
"
"
"
65
"
"
"
"
"
"
"
"
"
"
"
H
"
B
"
"
"
"
66
"
"
"
"
"
"
"
"
"
"
"
"
"
A
A
"
"
"
67
B
"
"
"
"
"
"
"
"
"
"
"
B
"
"
"
"
"
68
A
B
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
69
B
B
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
70
A
A
B
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
71
B
A
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
72
A
B
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
73
B
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
"
74
"
"
"
H
"
"
"
"
"
"
"
"
"
B
"
"
"
"
75
"
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
76
A
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
77
"
"
"
"
H
"
"
"
"
"
"
"
"
B
"
"
"
"
78
"
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
79
B
A
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
80
"
"
"
"
"
H
"
"
"
"
"
"
"
B
"
"
"
"
81
"
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
82
A
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
83
"
"
"
"
"
"
H
"
"
"
"
"
"
B
"
"
"
"
84
"
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
85
B
B
A
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
86
"
"
"
"
"
"
"
"
H
"
"
"
"
B
"
"
"
"
87
"
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
88
A
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
89
"
"
"
"
"
"
"
"
"
H
"
"
"
B
"
"
"
"
90
"
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
91
B
A
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
92
"
"
"
"
"
"
"
"
"
"
H
"
"
B
"
"
"
"
93
"
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
"
94
A
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
95
A
"
"
"
"
"
"
"
"
"
"
"
"
B
"
"
"
Same tests and terminal conditions as for subgroup 7 except TC = +125C and TC = -55C.
8
See footnotes at end of device type 05.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |