| TABLE III. Group A inspection for device type 02 Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V or low ≤ 0.8 V or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
MIL-STD-
C,D
Subgroup
Symbol
883
Case 1/
2
3
4
6
8
9
10
12
13
14
16
18
19
20
Measured
Limits
Unit
method
2
terminal
A2
B2
GND
B3
A3
B4
A4
VCC
Test no.
A1
B1
Min
Max
Y1
Y2
Y3
Y4
A
250
1
ICEX
3009
41
5.5 V
0.8 V
4.5 V
5.5 V
5.5 V
GND
5.5 V
5.5 V
5.5 V
5.5 V
4.5 V
Y1
Tc = 25C
"
42
0.8 V
5.5 V
4.5 V
5.5 V
"
"
"
"
"
"
"
"
"
Y1
"
"
"
43
5.5 V
"
0.8 V
"
4.5 V
"
"
"
"
"
"
Y2
"
"
"
44
"
"
5.5 V
0.8 V
4.5 V
"
"
"
"
"
"
Y2
"
"
"
45
"
"
"
5.5 V
"
4.5 V
"
0.8 V
"
"
"
Y3
"
"
"
46
"
"
"
"
"
4.5 V
0.8 V
5.5 V
"
"
"
Y3
"
"
"
47
"
"
"
"
"
5.5 V
"
4.5 V
"
0.8 V
"
Y4
"
"
"
48
"
"
"
"
"
"
"
4.5 V
0.8 V
5.5 V
"
Y4
ICCL
3005
49
"
"
"
"
"
"
"
5.5 V
5.5 V
5.5 V
VCC
30
mA
ICCH
3005
50
0.0 V
0.0 V
0.0 V
0.0 V
"
0.0 V
0.0 V
0.0 V
0.0 V
5.5 V
VCC
7
mA
Same tests, terminal conditions and limits as for subgroup 1, except TC = +125C and VIC tests are omitted.
2
Same tests, terminal conditions and limits as for subgroup 1, except TC = 55C and VIC tests are omitted.
3
7
Func-
3014
51
B
B
H
B
B
H
GND
H
B
B
H
B
B
3/
All
Tc = 25C
tional
"
52
A
B
"
A
B
"
"
"
B
A
"
B
A
"
outputs
tests
"
53
B
A
"
B
A
"
"
"
A
B
"
A
B
"
"
4/
"
54
A
A
L
A
A
L
"
L
A
A
L
A
A
"
"
6.5
12.5
ns
9
tPLH
3003
55
IN
2.7 V
OUT
GND
5.0 V
A1 to Y1
Tc = 25C
Fig. 3
56
2.7 V
IN
OUT
"
"
"
"
"
B1 to Y1
"
"
"
"
57
IN
2.7 V
OUT
"
"
A2 to Y2
"
"
"
"
58
2.7 V
IN
OUT
"
"
B2 to Y2
"
"
"
"
59
"
OUT
2.7 V
IN
"
A3 to Y3
"
"
"
"
60
"
OUT
IN
2.7 V
"
B3 to Y3
"
"
"
"
61
"
OUT
2.7 V
IN
"
A4 to Y4
"
"
"
"
62
"
OUT
IN
2.7 V
"
B4 to Y4
1.0
5.0
"
tPHL
"
63
IN
2.7 V
OUT
"
"
A1 to Y1
"
"
"
"
64
2.7 V
IN
OUT
"
"
B1 to Y1
"
"
"
"
65
IN
2.7 V
OUT
"
"
A2 to Y2
"
"
"
"
66
2.7 V
IN
OUT
"
"
B2 to Y2
"
"
"
"
67
"
OUT
2.7 V
IN
"
A3 to Y3
"
"
"
"
68
"
OUT
IN
2.7 V
"
B3 to Y3
"
"
"
"
69
"
OUT
2.7 V
IN
"
A4 to Y4
"
"
"
"
70
"
OUT
IN
2.7 V
"
B4 to Y4
Same tests and terminal conditions as for subgroup 9, except TC = +125 C and use limits from table I.
10
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55 C.
11
See footnotes at end of device type 03.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |