MIL-M-38510/382B
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions
Device
Limits
Unit
-55 TC +125
type
Min
Max
C
C
unless otherwise specified
Propagation delay time
tPHL1
VCC = 5.0 V,
03, 04
6
24
ns
CL = 50 pF 10%,
to low level (clear or preset
RL = 500
to output)
Propagation delay time to
tPLH2
01
8
27
ns
high level (enable to output)
02, 03
8
29
04
8
31
Propagation delay time to
tPHL2
01
8
20
ns
low level (enable to output)
02, 03,
8
22
04
Propagation delay time to
tPLH3
01, 03
2
15
ns
high level (data to output)
02
3
21
04
3
23
Propagation delay time to
tPHL3
01, 03
2
15
ns
low level (data to output)
02, 04
3
15
Output control on to high level
tPZH
All
4
21
ns
output
Output control on to low level
tPZL
All
4
21
ns
output
High level output to output
tPHZ
01
2
12
ns
control off
02, 03,
2
10
04
Low level output to output
tPLZ
01
3
18
ns
control off
02, 04
3
15
03
2
15
1/ The output conditions have been chosen to produce a current that closely approximates one-half of the true short
circuit output current, IOS.