TABLE III. Group A inspection for device type 02 - Continued.
For terminal conditions see table IIIA. Terminals not designated are open.
Case E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
Case F
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2
terminal
Test no.
VCC1
1A
1B
2A
2B
VEE
4Y
3A
3B
4A
4B
VCC2
Min
Max
1Y
2Y
3Y
4Y
1
IEE
41
GND
E1
GND
VEE
-26
mA
Tc = 25C
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-29
mA
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-29
mA
A
1
IIH1
42
GND
VIH1
E1
GND
1A
265
Tc = 25C
43
"
VIH1
"
"
1B
"
"
44
"
VIH1
"
"
2A
"
"
45
"
VIH1
"
"
2B
"
"
46
"
"
VIH1
"
3A
"
"
47
"
"
VIH1
"
3B
"
"
48
"
"
VIH1
"
4A
"
"
49
"
"
VIH1
"
4B
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
A
2
450
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
A
3
450
A
1
IIL
50
GND
VIL1
"
"
1A
0.5
Tc = 25C
51
"
VIL1
"
"
1B
"
"
52
"
VIL1
"
"
2A
"
"
53
"
VIL1
"
"
2B
"
"
54
"
"
VIL1
"
3A
"
"
55
"
"
VIL1
"
3B
"
"
56
"
"
VIL1
"
4A
"
"
57
"
"
VIL1
"
4B
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
A
2
0.3
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
A
3
0.5
9
tTLH
3004
58
E3
OUT
LD2
IN
E2
LD2
LD2
LD2
E3
1.1
3.3
ns
1Y
Tc = 25C
"
59
"
LD2
OUT
IN
"
"
"
"
"
"
"
"
2Y
"
60
"
"
LD2
"
"
IN
OUT
"
"
"
"
"
3Y
"
61
"
"
"
"
"
IN
LD2
OUT
"
"
"
"
4Y
"
62
"
"
"
"
OUT
IN
"
LD2
"
4Y
"
"
"
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
4.0
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
4.0
ns
9
tTHL
3004
63
E3
OUT
LD2
IN
E2
LD2
LD2
LD2
E3
1.1
3.3
ns
1Y
Tc = 25C
"
64
"
LD2
OUT
IN
"
"
"
"
"
"
"
"
2Y
"
65
"
"
LD2
"
"
IN
OUT
"
"
"
"
"
3Y
"
66
"
"
"
"
"
IN
LD2
OUT
"
"
"
"
4Y
"
67
"
"
"
"
OUT
IN
"
LD2
"
4Y
"
"
"
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
4.0
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
4.0
ns
9
tPLH
3003
68
E3
OUT
LD2
IN
E2
LD2
LD2
LD2
E3
1.0
2.9
ns
1Y
Tc = 25C
"
69
"
LD2
OUT
IN
"
"
"
"
"
"
"
"
2Y
"
70
"
"
LD2
"
"
IN
OUT
"
"
"
"
"
3Y
"
71
"
"
"
"
"
IN
LD2
OUT
"
"
"
"
4Y
"
72
"
"
"
"
OUT
IN
"
LD2
"
4Y
"
"
"
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
3.7
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
3.7
ns
9
tPHL
3003
73
E3
OUT
LD2
IN
E2
LD2
LD2
LD2
E3
1.0
2.9
ns
1Y
Tc = 25C
"
74
"
LD2
OUT
IN
"
"
"
"
"
"
"
"
2Y
"
"
"
"
75
"
"
LD2
"
"
IN
OUT
"
"
3Y
"
76
"
"
"
"
"
IN
LD2
OUT
"
"
"
"
4Y
"
77
"
"
"
"
OUT
IN
"
LD2
"
4Y
"
"
"
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
3.7
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
3.7
ns