MIL-M-38510/62B
2.3 Order of precedence. In the event of a conflict between the text of this specification and the references cited
herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws
and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Qualification. Microcircuits furnished under this specification shall be products that are manufactured by a
manufacturer authorized by the qualifying activity for listing on the applicable qualified manufacturers list before
contract award (see 4.3 and 6.3).
3.2 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535 and as
specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the
QM plan shall not affect the form, fit, or function as described herein.
3.3 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be
as specified in MIL-PRF-38535 and herein.
3.3.1 Logic diagrams and terminal connections. The logic diagrams and terminal connections shall be as
specified on figure 1.
3.3.2 Truth tables and logic equations. The truth table and logic equations shall be as specified on figure 2.
3.3.3 Schematic circuits. The schematic circuits shall be maintained by the manufacturer and made available to
the qualifying activity and the preparing activity upon request.
3.3.4 Case outlines. Case outlines shall be as specified in 1.2.3.
3.4 Lead material and finish. Lead material and finish shall be in accordance with MIL-PRF-38535 (see 6.6).
3.5 Electrical performance characteristics. The electrical performance characteristics are as specified in table 1
and apply over the full recommended case operating temperature range, unless otherwise specified.
3.6 Electrical test requirements. The electrical test requirements for each device class shall be the subgroups
specified in table II. The electrical tests for each subgroup are described in table III.
3.7 Marking. Marking shall be in accordance with MIL-PRF-38535.
3.8 Microcircuit group assignment. The devices covered by this specification shall be in microcircuit group
number 29 (see MIL-PRF-38535, appendix A).