MIL-M-52182E
Tunnel not placed and secured in the tank as specified for level A.
Drains in the tank not left open as specified for level A.
Oil lines not closed and capped as specified for level A.
Surfaces requiring a contact preservative in accordance with
referenced document not coated as specified for level A.
Drum hoist not placed in box, immobilized, and box sealed as specified
129.
for level A,
Technical publications not secured to the melter as specified for
level A.
Maintenance tools not preserved in accordance with the referenced
document for level A.
132.
Consolidation not as specified for level A.
Asphalt hose and hot-oil piping not secured in tunnel  as specified for
133.
1evel A.
Preservation and packing not in accordance with the referenced
134.
document as specified for commercial.
Blocking, bracing, and anchoring not as specified for level A.
Marking missing, illegible, incorrect, or incomplete for level A or
commercial.
PACKAGING
5.
Preservation shall be level A or commercial as specified
5.1 Preservation.
(see 6.2).
Level A.
5.1.l
5.1.1.1 Disassemble.  The dedrumming tunnel shall be removed from the melting
and storage tank.  The tunnel shall be placed in the melting and storage tank
and secured.  The drains in the tank shall be left open.  Oil lines shall be
closed with the caps provided.
5.1.1.2 Unpainted metal surfaces.  Unpainted metal surfaces of the asphalt
melter, fittings, drum hoist, etc., requiring the application of a contact
preservative in accordance with MIL-P-116 shall be coated with type P-l
preservative.  The preservative shall conform to the applicable specification
listed in and shall be applied in accordance with MIL-P-116.
5.1.1.3 Drum hoist.  When a drum hoist is specified it shall be placed in a
close fitting box conforming to PPP-B-636, type CF, class weather-resistant,
variety as applicable to the weight.  The hoist shall be immobilized within the
box to prevent movement.  BOX closure and sealing shall be in accordance with
the appendix to the box specification as specified for method V.
5.1.1.4 Technical publications.  Technical publications when applicable,
shall be preserved in accordance with MIL-P-116, method lC-1, or IC-3, and
secured to the melter in 2 protected location with tape conforming to
MIL-T-22O85, type II.