MIL-N-81604C(AS)
Table IX. IMU SYNCHRO AND RESOLVER CHARACTERISTICS
*Prior to IMU Ready, Platform Heading (X8) outputs and the S1
and S3 output leads of Platform Heading (Xl) shall be avail-
able external to the IMU and may be internally excited by the
IMU with 4.8 KHz excitation voltage. The load impedance across
*
the resolver outputs shall not be less than 1K ohms at that
frequency.
**All external loads shall be connected to synchro or resolver
stator leads.