4.4.4 End Item dimensional inspection.  The end items shall be examined for
conformance to the dimensions specified on the drawings.  Only those dimensions
that can be evaluated without damaging or disassembling the end items shall be
examined.  Any dimension not within the specified tolerance shall be classified
as a defect.  The lot size shall be expressed in units of press sections.  The
sample unit shall be one press section.  The inspection level shall be S-2 and
the AQL, expressed in terms of defects per hundred units, shall be 4.0.
4.4.5 End item testing.  Every press section shall be tested as specified in
4.5.1.  Any test failure shall be cause for rejection of the press section
tested.