MIL-P-45694(Ord)
TABLE I - CLASSIFICATION OF DEFECTS (Cont'd)
MINOR: AQL 4.0%
Req't
Par. QA.
Par..
Test Method
201.
Improper  spin  over  of
Dwg FT689472
Visual
pivot
4.6.3
202.  Illegibility  of
3.7
Visual
marking
4.6.6
203.  Improper  identification
3.10
Visual
marking
204.  Workmanship
3.4
4.6.7
Visual
TABLE II -
CLASSIFICATION OF DEFECTS
Use Inspection Level I, and Sampling Plan Table V of
Standard  MIL-STD-105
CRITICAL: NONE DEFINED
QA. Par.
Test Method
MAJOR:
AQL 1.5%
Req't
Par.
101.
Operating
temperature
3.5.1
4.6.1.1
Standard Measure
Equipment(SME)
102.  Storage  temperature
3.5.2
4.6.1.2
SME
103. Evidence of damage
4.6.1.2
3.5.2
Visual-Tactile
or  defects  subse-
quent  to  storage
temperature  test
4.6
Test
methods.
4.6.1
Environmental
testing.
4.6.1.1  Operating  temperature.-  The  operating  temperature  test
shall be conducted in accordance with Procedure I of Specification
MIL-F-13926,  except  that  the  conditions  specified  in  3.5.1  shall
a p p l y .  W h e n  t h e r m a l  s t a b i l i z a t i o n  iS r e a c h e d  a t  t h e  s p e c i f i e d
exposures,  respectively,  the  plotting  board  shall  be  tested  in
accordance  with  4.6.2  through  4.6.5  to  determine  cornpliance  with  the
requirements  of  3.5.1.