| MIL-P-46320C(MU)
4.7.1 Classification of defects and sampling
value specified shall apply to each individual
plans. Examination and testing to determine
characteristic on a single defect basis.
acceptance or rejection in compliance with
the applicable requirements of Section 3
4.7.1.1 Disposition of rejected lots. Re-
shall be conducted on a 100 percent inspec-
jected lots shall be screened in conformance
tion basis, initially. After conclusive evi-
to 4.4.1 for all defective characteristics
dence of the process average has been es-
causing rejection of the lot. After the Gov-
tablished in conformance with MIL-STD-
ernment inspector has approved the correc-
105 and the AQL's specified herein, the
tive action taken, subsequent production lots
classification of defects and sampling plans
specified in tables V and VI may be used
may be submitted for acceptance in accord-
in lieu of 100 percent inspection. The AQL
ance with 4.7.1 and MIL-STD-105.
TABLE V. Classification of defects
Use inspection level II in table III-A with sampling plan table IV-A of MIL-STD-105.
Critical: None defined
Requirement
Major: AQL 0.65%
Paragraph
Test method
QA. paragraph
101. Construction, nonconforming . . . . . . . . . . . . . . . . . . . . . . 3.3
4.8.1.1
Visual-Tactile-Standard
Measuring Equipment
(SME)
External surfaces, nonconforming . . . . . . . . . . . . 3.2.1
102.
4.8.1.2
SME-Visual
103. Physical failure, post vibration . . . . . . . . . . . . . . . . . . 3.7.4
4.8.1.6
Visual-Tactile
104. Input polarity, incorrect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.8.1
4.8.1.9
SME
105. Input impedance, incorrect . . . . . . . . . . . . . . . . . . . . . . . . 3.8.3
4.8.1.11
Special Testing Equipment
(STE) -SME
106. Output polarity, incorrect . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.8.4
4.8.1.12
SME
107. Intermittent operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.8.6
4.8.1.14
STE-SME
108. High voltage breakdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.12
4.8.1.16
Visual-Audio
109. Input current excessive . . . . . . . . 3.9.2
4.8.1.17.1
STE-SME
110. Output voltage regulation error . . . . . . . 3.9.3.1
4.8.1.17.2.1 STE
111. Output voltage error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.9.3.2
4.8.1.17.2.2 STE
112. Maximum output voltage excessive . . . . . 3.9.3.3
4.8.1.17.2.3 STE
Minor: None defined
Note. The above tests shall be conducted at standard ambient temperature (plus 60 to plus 90 Fahrenheit) in accordance with
the Quality Assurance ( QA. par. ) listed.
TABLE VI. Classification of defects
Use inspection level L6 in table III-B with sampling plan table IV-A of MIL-STD-105.
Critical: None defined
Requirement
Test method
Major AQL 4.0%
paragraph
QA.paragraph
Special Testing Equipment
4.8.1.17.1
101. Input current excessive . . . . . . . . . . . . . 3.9.2
(STE).
Standard Measuring Equip-
ment (SME).
4.8.1 .17.2.1 STE
102. Output voltage regulation error . . . . . . . 3.9.3.1
103. Maximum output voltage excessive . . . . . . 3.9.3.3
4.8.1 .17.2.3 STE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.9.3.4
4.8.1 .17.3
STE-SME
104. Rise time excessive
106. Ripple excessive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.9.3.5
4.8.1 .17.4
SME
106. Leakage (sealing) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.7.5
4.8.1.8
Visual
Minor. None defined
Note. The above teste shall be conducted at ambient temperature of minus 40" and Plus 186" Fahrenheit in accordance with the
quality assurance paragraph ( QA. Par. ) listed, except the sealing teat which shall be conducted at standard ambient temperature
subsequent to the operating test.
6
|