Back
Figure 8. Output capacitor voltage measurement
Up
Projectile, 155MM, HE, M692 and M731 Housing, Timing and Fuzing
Next
Gas generator firing circuit



img
MIL-P-48189D (AR)
APPENDIX A
the S.U.T. shall be connected as shown
40.2.7  Detonator firing circuit.
in Figure 9.* A minimum of 176 pulses shall be input on
followed by 1
pulse input on Z.  The output on P shall be measured and shall meet the
requirements in Table I, after Z has an input.
* Quick charge the capacitor to VB by closing SW1 before the input of
176 pulses.  Then open SW1 before giving an input to Z and measuring the
output on F.
Detonator output measurement.
FIGURE 9.
83