MIL-P-48602(MU)
N O T E : The tests in Table II shall be conducted at a temperature between
+ 6 0 and +90F.
4.4.2 Environmental.- Three plotting boards, without case, shall be
s e l e c t e d at random as samples from each 50 produced, or from each month's
production, whichever occurs first. Each sample shall meet the requirements
and tests in Table III, and shall then meet the requirements and tests in
Table I.
TABLE III
REQUIREMENT TEST PROCEDURE
NO. CHARACTERISTIC
3.3.1
4.6.1
303. Storage temperature
( - 5 0 and +140F)
3.3.2
4.6.2
304. Operability
( - 4 0 and +125F)
4 . 4 . 3 Failure of sample.- Should any one item of a special sampling
fail to meet the specified test requirements, acceptance of the represented
i n s p e c t i o n lot will be suspended by the Government until necessary correc-
t i o n s have been made by the contractor and resubmitted items have been
approved (see 4.3.3).
4.5 Inspection equipment.- Except as otherwise provided for by the
contract, the contractor shall supply and maintain inspection equipment in
a c c o r d a n c e with the applicable requirements of MIL-I-45607.
4.5.1 Government furnished inspection equipment.- Where the contract
p r o v i d e s for Government furnished test equipment, supply and maintenance of
test equipment shall be in accordance with the applicable requirements speci-
f i e d in MIL-I-45607.
4.5.2 Contractor furnished inspection equipment.
4.5.2.1 Government design.- All inspection equipment specified by
d r a w i n g number in specification or SQAP forming a part of the contract shall
b e supplied by the contractor in accordance with technical data included in
the technical data package list.
4.5.2.2 Contractor design.- In the absence of Government inspection
equipment designs, the contractor shall design and supply inspection equip-
m e n t compatible with the "Test Methods and Procedures" specified in 4.6 of
this specification and with the component inspection procedures specified
i n "Examination" and "Test Facilities" requirements of MIL-F-13926. Since
t o l e r a n c e of test equipment is normally considered to be within 10% of the
product tolerance for which it is intended, this inherent error in the test
e q u i p m e n t design must be considered as part of the prescribed product toler-
ance limit. Thus, concept, construction, materials, dimensions and tolerances
6