MIL-P-48619(AR)
specified torque to the eccentric. Then, while still observing the
eccentric, apply, in a counterclockwise direction, the specified
torque to the eccentric. To conform to the requirements of 3.5.8,
there shall be no rotation of the eccentric when observed during
each torque application.
4.6.2.9 Objective focusing mechanism - Daylight. -Back off the
locking screw of Housing 11727432 a minimum of two full revolutions
from its locked position.  Torque shall be measured while rotating
the eccentric through the range specified in 3.5.9.  The running
torque required to rotate the eccentric shall conform to the
applicable requirements of 3.5.9 for the temperatures indicated.
Upon completion of this test, return the eccentric to the position
in 3.8.2 and torque the locking screw as specified in 3.5.8. Peri-
scopes which have passed the above tests of 4.6.2.1 through 4.6.2.9
inclusive, shall be subjected to the tests in 4.6.3.
4.6.3 Vibration/Shock (Periscope].
4.6.3.1 Collimation, Pre-Vibration/Pre-Shock setting. -This test
and the following test of4.6.3.6 shall be performed with the
periscope positioned and adjusted as in 4.6.6. Prior to performing
these tests, disengage the index pin "D" from the index plate of the
test fixture and place the 10 second level on Surface "C" of the
leveling base.  The bubble of the level shall be centered within its.
graduation lines.  If it is not, then further adjustment is required
in accordance with the procedures prescribed in paragraphs 7 and 8
of the set-up instructions contained on Dwg. 8247391. With the
index pin "D" disengaged from the index plate and surface "C" of the
leveling base level, view through each periscope eyepiece (daylight
and passive) and obtain coincidence of each periscope reticle bore-
sight cross respectively, and the projected target image cross-lines
by means of the boresight knobs (do not slip knob scales). When
coincidence has been obtained, record the boresight knob scale
settings for use in the test in 4.6.3.6.
NOTE:
Insure that knob scales are not disturbed (re-slipped) from
their original recorded settings throughout remainder of
tests herein.
21