4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection shall be in accordance with
MIL-PRF-18546, and as specified herein.
4.2 Terminal strength. The direct pull shall be as specified in table IV.
TABLE IV. Direct pull.
Style
Direct pull (pounds)
RE60
5 +0, -1/4
RE65
5 +0, -1/4
RE70
10 +0, -1/2
RE75
10 +0, -1/2
4.3 Dielectric withstanding voltage.
4.3.1 At atmospheric pressure. The magnitude of the test voltage shall be as specified in table V.
TABLE V. Dielectric withstanding voltages at atmospheric pressure.
Style
Dielectric withstanding
test voltage (volts)
RE60
1,000
RE65
1,000
RE70
1,000
RE75
2,000
4.3.2 At reduced barometric pressure. The magnitude of the test voltage shall be 500 volts.
4.4 Chassis dimensions. The chassis dimensions shall be as specified in table VI.
TABLE VI. Chassis dimensions. 1/
Style
Length, width, and height
Thickness
RE60
6X4X2
0.04
RE65
6X4X2
0.04
RE70
7X5X2
0.04
RE75
7X5X2
0.04
1/ All dimension are given in inches.