ENVIRONMENTAL DATA:
Temperature range: Symbol B (-65C to +125C).
Internal moisture: Applicable.
Vibration: Symbol 4 (20 G, 10 Hz to 2,000 Hz).
Acceleration: Applicable.
Shock: Symbol 3 (100 G).
Resistive to solvents: Applicable.
Magnetic interference (adjacent-similar-relay): Applicable.
PHYSICAL:
Terminal strength: 3 0.3 pounds pull.
Dimensions and configuration: See figure 1 and table I.
Termination: See table I.
Weight: .125 pound (56.7 grams) maximum.
LIFE TEST REQUIREMENTS:
High level: 50,000 cycles.
Two relays per contact rating shall be tested, with rated loads on all contacts, except intermediate current.
Intermediate current: Level II (50,000 cycles).
Part or Identifying Number (PIN) M5757/23- (applicable dash number from table I).
6