Click here to make tpub.com your Home Page

Page Title: Table I. Operating characteristics
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
TABLE I. Operating characteristics.
Coil data
Time (milliseconds-maximum)
Nominal
Max
Max pick-up voltage
Bounce
Dash
Type
Drop
Hold
Oper-
Re-
Coil
out
voltage
ate
lease
No
Freq.
Res.
Volts
Amp-
Norm
High
Cont.
Volts
Main
Aux
2/
voltage
1/
Hz
eres
2/
temp
current
2/
NO
NC
NO
NC
test
test
-001
I
X1, X2
28
dc
30
0.6
18
19.8
22.5
7.0
1.5
25
10
1/
CAUTION: Use of any coil voltage less than nominal coil voltage will compromise the operation of the relay.
2/
Over the temperature range.
3/
With nominal coil voltage.
4/
From nominal coil voltage.
TABLE II. Rated contact load (amperes per pole) case grounded.
115/200 V ac, 3 phase 1/
28 V dc
115 V ac, 1 phase
Type
See
Life
of
notes
operating
Main
Aux
Main
Aux
Main
Aux
load
cycles
NO
NC
NO
NC
400 Hz
60 Hz
400 Hz
60 Hz
400 Hz
60 Hz
400 Hz
60 Hz
3
X 10
Resistive
50
50
50
5
5
Inductive
30
25
25
5
5
Motor
Lamp
50
10
10
.5
.5
Transfer
2/
load
Mechanical
100
12.5
12.5
life reduced
current
Mixed loads
1/ Absence of value indicates relay is not rated for 3-phase applications.
2/ Transfer load indicates the relay is suitable for transfer between unsynchronized ac power supplies at rating indicated.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business