MIL-R-83726/18G
ESDS preservation and packaging: Relays shall be preserved and packaged in such a manner as to
ensure that the integrity of ESD sensitive relays is not diminished. ESD sensitive relays shall be
preserved and packaged in accordance with the requirements of MIL-STD-1686.
PIN: Consists of the prefix M83726/18-, a four-digit dash number (expressed in milliseconds), and a
suffix letter (indicating the extent of EMI requirements) as follows:
83726/18-
1001
A
M
Military designator
Specification sheet number
The first three digits are significant;
the fourth digit is the number of zeros to
follow the first three digits. The time is
expressed in milliseconds and converted to
seconds. (See examples following table V.)
Suffix letter 7/
Examples:
M83726/18-1000W-100 millisecond time delay, with less stringent EMI requirements.
M83726/18-1001A-1 second time delay, with more stringent EMI requirements.
Quality assurance provisions: Group B and group C testing are not required. The
manufacturer shall notify the qualifying activity in the event of any design or construction
changes, and shall impose additional testing requirements as necessary.
The Qualified Products List (QPL) associated with this inactive for new design specification
will be maintained until acquisition of the product is no longer required, whereupon the
specification and the QPL will be canceled.
Custodian:
Preparing activity:
Navy - EC
DLA - CC
Air force - 11
DLA - CC
Review activities:
(Project 5945-1167-03)
Air Force 99
7/ Any relays numbered prior to the date of this specification with a suffix indication shall be considered
interchangeable (store and issue) with the W for relays with less stringent EMI requirements (Y,X) or
A for relays with more stringent EMI requirements (B,C).