| MIL-S-1419D (PA)
TABLE II
Code No.
Classification
Defect
Signal functions during
07012
Critical
test (see 3.4.1)
Signal not safe to
transport following
07013
Critical
test (see 3.4.2)
Signal damaged after
07014
Major
test (see 3.4.3)
Signal packing damaged
07015
Major
(see 3.4.4)
4.3.3.2.1 Beginning with the first lot produced and con-
tinuing until three (3) consecutive lots have complied with the
acceptance criteria specified, two hundred and forty (240)
signal assemblies shall be selected from each lot for test.
The lot shall be rejected if any defect as classified in
Table II occurs. The test shall be performed as specified
in 4.4.2.
4.3.3.2.2 After three (3) consecutive lots have complied
with the acceptance criteria of 4.3.3.2.1, eighty (80)signal
assemblies shall be selected from each lot for test. The lot
shall be rejected if any defect as classified In Table II occurs.
*4.3.3.3 Functioning. - The signal assemblies shall be ob-
served for any evidence of failure to comply with the requirements
as classified in Table 111 when tested as specified In 4.4.3.
TABLE III
Code No.
Classification
Defect
Star color incorrect
07017
Critical
(see dwg. 3847463)
Star bursts In pistol
07018
Critical
(see 3.5.1)
Star burning time below
07019
Major
min. (see dwg. 8847463)
Altitude below min.
07020
Major
(see 3.5.4)
Primer fails to function
07021
Major
(see 3.5.3)
17
|