MIL-S-20517H (AR)
3 .4.3 Expelling time.  The charge case assembly shall not fail
to expel within 150 milliseconds on functioning of the primer.
3.4.4 Horizontal distance and altitude.  The charge case
assembly shall not burst at a horizontal distance of less than 100
feet from the pistol or at an altitude of less than 50 feet.
The primer shall not fail to
3.4.5 Primer functioning.
function.
The simulator shall show no evidence of
3.5 Air leakage test.
leakage.
3.6 First article inspection. This specification contains
technical provisions for first article i nspection.  Requirements for
the submission of first article samples by the contractor shall be
as specified in the contract.
3.7 Workmanship.  All parts shall be fabricated and finished in
a thorough workmanlike manner, and all manufacturing, processing and
assembly operations shall be correctly performed.  They shall be
clean and free of burrs, sharp edges, unblended radii, surface
defects, chips, dirt, grease, oil, corrosion products and other
foreign matter.  The cleaning method used shall not be injurious to
any parts or assembly, nor shall the parts be contaminated by the
cleaning agent.  Exterior surface coatings shall be continuous
except for a few light scratches not exposing base material.  All
required markings shall be neat, legible and sharply defined.
Required packing shall be dry.
QUALITY ASSURANCE PROVISIONS
4.
4.1 Responsibility for inspection and standard quality
assurance provisions.  Unless otherwise specified herein or in the
contract, the provisions of MIL-A-48078 shall apply and are hereby
--
made a part of this detail specification.
4.2 Classification of inspections.  The following types of
inspection shall be conducted on this item:
First Article Inspection
a.
b.
Quality Conformance Inspection