Click here to make tpub.com your Home Page

Page Title: Test Method 3. Las Durability Test
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




MIL-S-52860D
APPENDIX
TEST METHOD 3
LAS DURABILITY TEST
1.
TEST APPARATUS:
a.
DC power supply - constant output or adjustable to provide a voltage of
20 0.3 Vdc at currents up to 40 mA, load regulation <0.5%, ripple <100
mv p-p, total voltage canmge due to ambient temperature change and drift
with time during the test period <0.5 Vdc.
b.  DC voltmeter - between 19 and 21 V minimum resolution 0.1 Vdc, minimum
accuracy 1.5%.
c.  DC ammeter - between 10 and 30 mA, minimum resolution 0.1 mA, minimum
accuracy 2%, maximum full scale voltage drop (burden voltage) 0.3 V.
d.  Ohmmeter - resolution 1 % of reading, accuracy 2% of reading.
2.
TEST PROCEDURE:
a.
Perform test method 1.
b.
Manually or mechanically activate switch S1, using the actuator.
c.
Manually or mechanically activate reset switch S2.
d.
Repeat steps b. and c. 1500 times each.
e.
Repeat test method 1.
17

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business