MIL-S-62095C(AT)
*  3.16.2.1 Noise level. If the noise level at the operator's position, when measured in
accordance with MIL-STD-1474, exceeds 84 decibels (dB(A)), a warning plate stating
"CAUTION: HEARING PROTECTION REQUIRED" shall be permanently affixed to the
semitrailer in a conspicuous location at the operator's position. The noise level shall be
determined with the vehicle stationary and the pumping system operating at a maximum engine
governed speed and maximum load. The plate shall conform to 3.1.1.8.
3.16.2.2 Exhaust system. The exhaust system shall be furnished with a spark arresting
muffler. The muffler shall have a heat shield. The tailpipe shall be pointed toward the rear end
and to the ground. The spark arrester shall have an 80 percent arresting efficiency when rated in
accordance with SAE J350.
*  3.16.2.3 Lights. In addition to the other lighting specified herein, lights with guards and
toggle switches suitable for illuminating the engine control panel shall be furnished.
*  3.16.2.4 Engine control panel. The engine throttle and a key-operated starting switch shall
be installed in a weather- and waterproof cabinet on a control panel, each identified as to their
function. The cabinet shall be fitted with a side hinged cover with a spring type latch and shall
provide for locking with a padlock.
3.16.3 Water tank outlet valve and controls. A tank outlet valve of the flanged type not less
than 75 mm (3 inches) in nominal diameter shall be provided. The outlet valve, when closed, shall
effectively seal the tank and shall be of a type permitting complete removal of the valve body.
Controls with slotted stops to hold the outlet valve at various openings shall be furnished and
located in the manifold cabinet. The outlet valve shall have a screen of small mesh that will not
unduly restrict the flow of water through the discharge piping. The screen shall be readily
removable for cleaning and shall be located on the inside of the tank over the valve mechanism.
3.16.4 Manifold. A manifold shall be provided having 75 mm (3-inch) gate valves and with
cam-locking connections designed to fit the hoses specified herein, arranged to provide the
following:
(a)
Gravity discharge of tank contents, bypassing the pump.
(b)
Pressure discharge of tank contents by use of the pump unit.
(c)
Filling of the tank through the filler opening, by utilizing the pump unit and the hoses
specified herein, from a non-pressurized source.
*  3.16.5 Instruction plate. A data plate, showing a schematic of all valves, components and
accessories with operating instructions, shall be fastened in a visible location inside the curbside
cabinet door. The plate shall conform to 3.1.1.8.